English 中文
HOT PRODUCTS
Crimp Headspace Vial1.5 ML/2ML 8-425 Screw Neck Autosampler Vials ND8
1.5 ML/2ML 8-425 Screw Neck Autosampler Vials ND8
Details Products name 1.5 ML/2ML 8-425 Screw Neck Autosampler Vials ND8 Dimension 8mm Cap Color White and Black Septa details White,Red,Blue,1.5mm thickness. Material PP for Cap, PTFE/Silicone for Septa Package 100pcs/Pack Cap type Close top, Open top Septa type Non-slit, Pre-slit Description 1.5 ml vials from Aijiren Technology, Inc with high quality and favorable price. Zhejiang Aijiren is a manufacturer of Laboratory consumables. We supply autosampler vials, septa and c...
Crimp Headspace Vial1.5ml 9mm Short Thread Autosampler Vials ND9
1.5ml 9mm Short Thread Autosampler Vials ND9
Details Products name 1.5mL 9mm Short Thread Autosampler Vial ND9 Dimension 9mm Cap Color Blue, Black, Red, Yellow Septa details White,Red,Blue,1mm thickness. Material PP for Cap, PTFE/Silicone for Septa Package 100pcs/Pack Cap type Close top, Open top Septa type Non-slit, Pre-slit Description 1.5 ml vials from Aijiren Technology, Inc with high quality and favorable price. Zhejiang Aijiren is a manufacturer of Laboratory consumables. We supply autosampler vials, septa and ...
Crimp Headspace Vial1.5ml 10-425 Screw Autosampler Vials ND10
1.5ml 10-425 Screw Autosampler Vials ND10
Details Products name 1.5ml 10-425 Screw Autosampler Vials ND10 Dimension 10mm Cap Color Black Septa details White,Red,1.5mm thickness. Material PP for Cap, PTFE/Silicone for Septa Package 100pcs/Pack Cap type Open top Septa type Non-slit Description 1.5 ml vials from Aijiren Technology, Inc with high quality and favorable price. Zhejiang Aijiren is a manufacturer of Laboratory consumables. We supply autosampler vials, septa and caps at factory price. 1.  1.5ml 10-425 Scre...
Crimp Headspace Vial1.5mL 11mm Crimp Ring Autosampler Vial ND11
1.5mL 11mm Crimp Ring Autosampler Vial ND11
Details Products name 1.5mL 11mm Crimp Ring Autosampler Vial ND11 Dimension 11mm Cap Color Silver Septa details White, Red,1mm thickness. Material Aluminum for Cap, PTFE/Silicone for Septa Package 100pcs/Pack Cap type Open top Septa type Non-slit, Pre-slit Description 1.5 ml vials from Aijiren Technology, Inc with high quality and favorable price. Zhejiang Aijiren is a manufacturer of Laboratory consumables. We supply autosampler vials, septa and caps at factory price. 1. ...
Crimp Headspace Vial1.5mL 11mm Snap Ring Autosampler Vial ND11
1.5mL 11mm Snap Ring Autosampler Vial ND11
Details Products name 1.5mL 11mm Snap Ring Autosampler Vial ND11 Dimension 11mm Cap Color Natural, Blue, Red Septa details White, Red, Blue,1mm thickness. Material PE for Cap, PTFE/Silicone for Septa Package 100pcs/Pack Cap type Open top Septa type Non-slit, Pre-slit Description 1.5 ml vials from Aijiren Technology, Inc with high quality and favorable price. Zhejiang Aijiren is a manufacturer of Laboratory consumables. We supply autosampler vials, septa and caps at factory...
Crimp Headspace Vial4mL 13-425 Screw Neck Autosampler Vial ND13
4mL 13-425 Screw Neck Autosampler Vial ND13
Details Products name 4mL 13-425 Screw Neck Autosampler Vial ND13 Dimension 13mm Cap Color Black Septa details White, Red, Nature 1.5mm thickness. Material PP for Cap, PTFE/Silicone for Septa Package 100pcs/Pack Cap type Close top, open top Septa type Non-slit Description 4 ml vials from Aijiren Technology, Inc with high quality and favorable price. Zhejiang Aijiren is a manufacturer of Laboratory consumables. We supply autosampler vials, septa and caps at factory price. 1...
Crimp Headspace Vial16mm Test Tubes for Water Analysis
16mm Test Tubes for Water Analysis
Details Products name 16mm Test Tubes for Water Analysis Dimension 16mm Cap Color White Material PC for Cap, PTFE/Silicone for Septa Package 100pcs/Pack or 25pcs/Pack Cap type Close top Septa type Non-slit Description COD vials from Aijiren Technology, Inc with high quality and favorable price. Zhejiang Aijiren is a manufacturer of Laboratory consumables. We supply autosampler vials, Headspace vials and COD vials at factory price. 1. PTFE Septa for 16mm test tube Closures, W...
Crimp Headspace Vial20-60mL 24-400 Screw Neck Storage Vial ND24
20-60mL 24-400 Screw Neck Storage Vial ND24
Details Products name 20-60mL 24-400 Screw Neck Storage Vial ND24 Dimension 24mm Cap Color Black, White Septa details Nature,3mm thickness. Material PP for Cap, PTFE/Silicone for Septa Package 100pcs/Pack Cap type Open top, Close top Septa type Non-slit Description Sample Storage vials from Aijiren Technology, Inc with high quality and favorable price. Zhejiang Aijiren is a manufacturer of Laboratory consumables. We supply Sample Storage vials, septa and caps at factory pr...
Our Company
Zhejiang Aijiren Technology Co., Ltd. is a global supplier of Headspace Vials in the field of analysis with high quality, excellent service and preferential prices. Aijiren's customers come from the pharmaceutical, life sciences, chemistry, technology, food processing and other industries. These industries all need Headspace GC Vial for testing. Others such as universities, research institutions, governments, environmental testing institutions, etc. also often buy GC Vial from Aijiren for Gas Chromatography.
20
+ years
Experience Accumulation
Technical Improvement
200/30
Embloyees and Senior Engineers
Best GC Vial Production Process
10000
Square Meters of Floor Space
Advanced Production Scale and Capacity
300+
Analytical Laboratories
Government Infrastructure Project Partner
Total Customers All Over the World
Headspace Vial on Sale
GC Vial Supplier
GC Vial Manufacturer
Aijiren Headspace Vial
The Australian Customer’s V947 Autosampler Vial Order is CompletedCrimp Top Headspace Vial
The Australian Customer’s V947 Autosampler Vial Order is Completed
View More
American Customer Ordered 100,000 Boxes of 9-425 2ml HPLC VialsCrimp Top Headspace Vial
American Customer Ordered 100,000 Boxes of 9-425 2ml HPLC Vials
View More
5000-boxes-of-blue-screw-cap-10-425-hplc-vial-sent-to-singaporeCrimp Top Headspace Vial
5000-boxes-of-blue-screw-cap-10-425-hplc-vial-sent-to-singapore
View More
The chain has six links, and a certificate only covers one of themnew gc vial
The chain has six links, and a certificate only covers one of them
A lab I work with failed an ISO 17025 surveillance audit over a box of vials. Not a method, not an instrument, not a calibration. The assessor picked up a lot of 9 mm clear crimp vials, read the certificate of analysis, and asked the analyst to show the calibration certificate for the micrometer used to check the neck OD. The analyst could not. The micrometer had been in service for two years with no tag, no calibration record, and no link to the CoA that quoted a ±0.15 mm tolerance on that...
Extractables arrive as a compound class, not as a single mystery peaknew gc vial
Extractables arrive as a compound class, not as a single mystery peak
A 60 m DB-5MS run came back with a clean solvent front, a flat baseline, and then a perfectly repeatable pair of peaks at RT 14.82 and 15.06 min, each about 0.4 pA tall, present in every injection including the solvent blank. The analyst had already replaced the liner, trimmed 30 cm off the column, and baked the inlet at 320 °C overnight. None of it moved the peaks. The source was the vial: a lot of clear glass 2 mL crimp vials with a silicone/PTFE septum that had been stored in a warm room...
Which gc vial material to use for a given solvent and temperature starts withnew gc vial
Which gc vial material to use for a given solvent and temperature starts with
A 60 m x 0.25 mm x 0.25 µm DB-5 run on a soil extract came back with 14% area RSD on the internal standard across six injections, and the culprit was a 1 mm silicone-only septum in a crimp cap that had been on the vial for eleven hours before the autosampler got to it. The solvent was 1:1 dichloromethane:hexane. The septum had swollen, the injection port needle punched through a soft spot, and the resulting leak pulled air into the liner on every injection. That is a material selection fail...
Set the reorder point from lead-time variance, not from the quoted lead timenew gc vial
Set the reorder point from lead-time variance, not from the quoted lead time
A 2 mL clear glass vial, 9 mm screw thread, PTFE/silicone septum, order quantity 10,000. That was the line item that broke a purchasing model last spring: the buyer had been running a reorder point of 4,000 units against a stated 3-week lead time, and the first stockout still happened on a Tuesday morning with 1,800 vials left in the rack. The lead time hadn’t moved. The consumption rate had, quietly, by about 22% after a second autosampler came online. Nobody had touched the reorder ...